7Risk Axes

National percentile · lower = less risk · staffing gap is context only (not in composite)

How we calculate
SeverityLow

22th national percentile — 0.0% high-severity citations

ChronicityWatch

66th national percentile — 11 repeat citations

Staffing integrityClean

None on file

Fire safetyElevated

26 citations

Weekend staffing dropWatch

55th national percentile — 16.2%

Contract staff shareLow

17th national percentile — 0.0%

Clinical trendElevated

70th national percentile — 2/5 measures worsened

Staffing gapElevated

Reported 2.97 vs expected 3.30 · −0.34 hr/res/day

Recent Health Violations

Health inspection citations from official Medicare records

41 citations on file
F-0695
D
Provide safe and appropriate respiratory care for a resident when needed…
Minimal Harm

Provide safe and appropriate respiratory care for a resident when needed.

Survey date: Apr 2, 2026 · Isolated — no actual harm with potential for more
F-0684
D
Provide appropriate treatment and care according to orders, resident’s p…
Minimal Harm

Provide appropriate treatment and care according to orders, resident’s preferences and goals.

Survey date: Apr 2, 2026 · Isolated — no actual harm with potential for more
F-0881
E
Implement a program that monitors antibiotic use
Potential Harm

Implement a program that monitors antibiotic use.

Survey date: Apr 2, 2026 · Pattern — no actual harm with potential for more
F-0880
E
Provide and implement an infection prevention and control program
Potential Harm

Provide and implement an infection prevention and control program.

Survey date: Apr 2, 2026 · Pattern — no actual harm with potential for more

Recent Fire Safety Violations

Fire safety inspection citations from official Medicare records

26 citations on file
F-0353
E
Inspect, test, and maintain automatic sprinkler systems
Potential Harm

Inspect, test, and maintain automatic sprinkler systems.

Survey date: Apr 2, 2026 · Pattern — no actual harm with potential for more
F-0363
E
Install corridor and hallway doors that block smoke
Potential Harm

Install corridor and hallway doors that block smoke.

Survey date: Apr 2, 2026 · Pattern — no actual harm with potential for more
F-0374
D
Install smoke barrier doors that can resist smoke for at least 20 minute…
Minimal Harm

Install smoke barrier doors that can resist smoke for at least 20 minutes.

Survey date: Apr 2, 2026 · Isolated — no actual harm with potential for more
F-0511
E
Have properly installed electrical wiring and gas equipment
Potential Harm

Have properly installed electrical wiring and gas equipment.

Survey date: Apr 2, 2026 · Pattern — no actual harm with potential for more