7Risk Axes

National percentile · lower = less risk · staffing gap is context only (not in composite)

How we calculate
SeverityElevated

92th national percentile — 16.7% high-severity citations

ChronicityElevated

82th national percentile — 8 repeat citations

Staffing integrityClean

None on file

Fire safetyElevated

21 citations

Weekend staffing dropLow

1th national percentile — 5.2%

Contract staff shareElevated

88th national percentile — 14.6%

Clinical trendElevated

70th national percentile — 2/5 measures worsened

Staffing gapAligned

Reported 3.24 vs expected 2.58 · +0.66 hr/res/day

Recent Health Violations

Health inspection citations from official Medicare records

24 citations on file
F-0600
D
Protect each resident from all types of abuse such as physical, mental, …
Minimal Harm

Protect each resident from all types of abuse such as physical, mental, sexual abuse, physical punishment, and neglect by anybody.

Survey date: Jun 22, 2025 · Isolated — no actual harm with potential for more
F-0689
G
Ensure that a nursing home area is free from accident hazards and provid…
Actual Harm

Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.

Survey date: Jan 13, 2025 · Isolated — actual harm
F-0755
D
Provide pharmaceutical services to meet the needs of each resident and e…
Minimal Harm

Provide pharmaceutical services to meet the needs of each resident and employ or obtain the services of a licensed pharmacist.

Survey date: Jan 13, 2025 · Isolated — no actual harm with potential for more
F-0580
D
Immediately tell the resident, the resident's doctor, and a family membe…
Minimal Harm

Immediately tell the resident, the resident's doctor, and a family member of situations (injury/decline/room, etc.) that affect the resident.

Survey date: Oct 25, 2024 · Isolated — no actual harm with potential for more

Recent Fire Safety Violations

Fire safety inspection citations from official Medicare records

21 citations on file
F-0161
F
Use approved construction type or materials
Potential Harm

Use approved construction type or materials.

Survey date: Mar 13, 2025 · Widespread — no actual harm with potential for more
F-0311
F
Have an enclosure around a vertical opening shaft
Potential Harm

Have an enclosure around a vertical opening shaft.

Survey date: Mar 13, 2025 · Widespread — no actual harm with potential for more
F-0321
E
Ensure that special areas are constructed so that walls can resist fire …
Potential Harm

Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.

Survey date: Mar 13, 2025 · Pattern — no actual harm with potential for more
F-0353
F
Inspect, test, and maintain automatic sprinkler systems
Potential Harm

Inspect, test, and maintain automatic sprinkler systems.

Survey date: Mar 13, 2025 · Widespread — no actual harm with potential for more

Better Nearby Options

Within 25 km · sorted by overall risk percentile

Full nearby list
Facility
CMS
Risk %ile
Tier
DOBSON PLAZA
22.6 km · EVANSTON, IL
★★★★★
CMS
22th
Risk %ile
Lower risk
VI AT THE GLEN
11.0 km · GLENVIEW, IL
★★★★★
CMS
24th
Risk %ile
Lower risk
CITADEL CARE CENTER-WILMETTE
19.8 km · WILMETTE, IL
★★★★★
CMS
31th
Risk %ile